awwa c210 c213 3 layer polyethylene cold applied tape

ANSI/AWWA C213 :2015 FUSION-BONDED EPOXY

ANSI/AWWA D107-16 ERR 1(CSV) COMPOSITE ELEVATED TANKS FOR WATER STORAGE:ASTM A 1042/A1042M :2004 :Standard Specification for Composite Corrugated Steel Pipe for Sewers and Drains:AWWA C209 :2013 :COLD-APPLIED TAPE COATINGS FOR STEEL WATER PIPE, SPECIAL SECTIONS, CONNECTIONS, AND FITTINGS:ANSI/AWWA C200 :2017 :STEEL WATER PIPE, 6

API 5LPSL1/PSL 2,AS 2885-1,ISO 3183-1/2/3,EN10208

2.1.6 Tape Coating ISO 21809-3:2008, Petroleum and natural gas industries-External coatings for buried or submerged pipelines used in pipeline transportation systems-Part 3:Field joint coatings AWWA C209-00:Standard for Cold-Applied Tape Coatings for the Exterior of Special Sections, Connections, and Fittings for Steel Water Pipelines AWWA C200,ASTM A139,ASTM A252,EN 10217-1,EN AWWA C210 Standard for Liquid-Epoxy Coating Systems for the Interior and Exterior of Steel Water Pipelines. AWWA C213 Standard for Fusion Bonded Epoxy Coating for the Interior and Exterior of Steel Water Pipelines NFA 49-709 Internal can be epoxy 80 microns NFA 49-708 Recommended Practice for Internal Coating of Line Pipe. 3.2.2 Bitumen Lining

AWWA C210,AWWA C215,ISO 12944,EN

AWWA C210 Standard for Liquid-Epoxy Coating Systems for the Interior and Exterior of Steel Water Pipelines. AWWA C213 Standard for Fusion Bonded Epoxy Coating for the Interior and Exterior of Steel Water Pipelines. BP GIS 06-402 Guidance on Industry Standard for Fusion Bonded Epoxy Powder External Pipeline Coatings. AWWA C214-14 Tape Coatings for Steel Water PipeBack to AWWA C214-14 Tape Coatings for Steel Water Pipe. This standard describes the materials and application of tape coating systems in coating plants at fixed sites using coating techniques and equipment as recommended by the tape coating manufacturer. For normal construction considerations, prefabricated polyolefin tapes are applied as a three-layer system consisting of (1 ( liquid adhesive, (2) corrosion-preventive tape (inner layer), and (3) mechanical-protective tape (outer layer).

AWWA Standards Package - MADCAD

AWWA C209-06:Cold Applied Tape Coatings For The Exterior Of Special Sections, Connections, & Fittings For Steel Water Pipelines / 2006; AWWA C210-07:Liquid Epoxy Coating Systems For The Interior & Exterior Of Steel Water Pipelines / 2007; AWWA C213-07:Fusion Bonded Epoxy Coating For The Interior & Exterior Of Steel Water Pipelines / 2007 AWWA Standards Print-Full SetAWWA C209-19 Tape Coatings for Steel Water Pipe and Fittings; AWWA C210-15 Liquid-Epoxy Coatings and Linings for Steel Water Pipe and Fittings; AWWA C213-15 Fusion-Bonded Epoxy Coatings and Linings for Steel Water Pipe and Fittings; AWWA C214-20 Machine-Applied Polyolefin Tape Coatings for Steel Water Pipe

AWWA Steel Pipe Set - MADCAD

AWWA C209-06:Cold Applied Tape Coatings For The Exterior Of Special Sections, Connections, & Fittings For Steel Water Pipelines / 2006; AWWA C210-07:Liquid Epoxy Coating Systems For The Interior & Exterior Of Steel Water Pipelines / 2007; AWWA C213-07:Fusion Bonded Epoxy Coating For The Interior & Exterior Of Steel Water Pipelines / 2007 Copyright 2018 by American Water Works Association 1C209 -13 Cold-Applied Tape Coatings for the Exterior of Special Sections, Connections, and Fittings for Steel Water Pipelines Steel Pipe Steel Pipe 43209-2013 C210 -15 Liquid-Epoxy Coatings and Linings for Steel Water Pipe and Fittings Steel Pipe Steel Pipe 43210-2015 C213 -15 Fusion-Bonded Epoxy Coatings and Linings For Steel Water Pipe and

EN 10025,EN 10149,EN 10028,EN 10083,EN 10208 Plate

Apr 03, 2021 · AWWA C210 Standard for Liquid-Epoxy Coating Systems for the Interior and Exterior of Steel Water Pipelines NFA 49-710 External Three-Layer Polyethylene Based Coating, Application by Extrusion AWWA C209-00:Standard for Cold-Applied Tape Coatings for the Exterior of Special Sections, Connections, and Fittings for Steel Water Pipelines JANUARY 2021 - Fairfax WaterJul 10, 2017 · Enamel and Tape-Hot Applied C. ANSI/AWWA C205 - Cement-Mortar Protective Lining and Coating for Steel Water Pipe 4-inch and Large Shop Applied D. ANSI/AWWA C206 - Field Welding of Steel Water Pipe E. ANSI/AWWA C210 - Liquid Epoxy Coating Systems for the Interior and Exterior of Steel Water Pipelines

Pipelines 2011:A Sound Conduit for Sharing Solutions

AWWA Standard First Edition of AWWA Standard Portland Cement Mortar X X Before 1836 C104 C205 C602 1939 1941 1955 Coal Tar Enamel X X Mid 1930s 7A.4 & 7A.5 C203 C203 1940 1951 Coating 1973 Lining Liquid Epoxy X X 1950s C210 1978 Fusion-Bonded Epoxy X X 1960 (gas line) C213 1979 Tape X ~1960 C214 1983 ProtectionAWWA C213 American Water Works Association Standard for Fusion-Bonded Epoxy Coating For The Interior and Exterior of Steel Water applied, the result is a Dual Layer System that is chemically bonded at the layered layer, and a topcoat of polyethylene or

SECTION 15061 STEEL PIPE SPECIFICATION

ANSI/AWWA C209:Cold-Applied Tape Coatings for the Exterior of Special Sections, coated with epoxy paint conforming to ANSI/AWWA C210 or ANSI/AWWA C213. 5. Where tied joints are required, mechanical couplings shall be harnessed for the Contractor shall provide a polyethylene or other suitable bulkhead on the ends of San Antonio Water System Material Standard 1. Polyethylene Tape Coating . a) Prefabricated Multi-layer Cold Applied Tape Coating - the coating system for straight-line pipe shall be in accordance with AWWA Standard C214. The system shall consist of three layers of polyethylene material with a nominal thickness of 80

Section 327 IAC 8-3.2-8 - Water main materials, 327 Ind

Mar 24, 2021 · (G) C209-00 AWWA Standard for Cold-Applied Tape Coatings for the Exterior of Special Sections, Connections, and Fittings for Steel Water Pipelines. (H) C210-03 Liquid-Epoxy Coating Systems for the Interior and Exterior of Steel Water Pipelines. Standards List American Water Works AssociationThe American Water Works Association first published consensus documents in 1908. Today there are more than 180 AWWA Standards. From source to storage, from treatment to distribution, AWWA standards cover all areas of water treatment and supply.

Suggested Specification for Buried Steel Water

(Use for tape or polyurethane coated pipe) Coat the joint exterior by application of either a heat shrinkable sleeve conforming to AWWA C216, or cold applied tape conforming to AWWA C209. The applied thickness of the heat shrinkable sleeve shall be 70 mil minimum, or as recommended by the sleeve manufacturer, whichever is greater. The cold applied tape shall consist of two wraps of 30 mil tape Suggested Specification for Steel Water Transmission Pipec. (Use for tape coated pipe) Pipe shall be coated with prefabricated multi-layer cold-applied polyethylene tape coatings in accordance with AWWA C214. The tape shall be two layers for a total thickness of the coating of 80 mils for pipe diameters over 54 and 50

[DOC]Sec. 2.3:Steel Water Pipe - Dallas

 · Web viewFittings shall be lined and coated per AWWA C205. Fittings too small to cement mortar line may be lined with AWWA C210 epoxy or AWWA C222 polyurethane. 3.2.3 Polyethylene Tape Coating. 3.2.3.1 The prefabricated multi-layer cold applied tape coating system for straight-line pipe shall be in accordance with AWWA C214.AWWA Coa ng Standards for Water PipeAWWA C203-08 AWWA C205-12 AWWA C209-06 AWWA C210-07 AWWA C213-07 AWWA C214-07 AWWA C215-10 AWWA C218-08 AWWA C222-08 AWWA C225-07 Machine Applied Tape Strengths:High throughput systems allow coaters to wrap pipe at high pro-duction rates. Weaknesses:Polyethylene outer layer (high density) has limited UV resistance